Infant Incubator BabyGuard Transformer
Choose model — 2 available
Dixion
Article No. AK-OG-013
For the provision of a similar maternal uterus environment for the neonate to provide stable and controlled comfortable thermal environment and servo-controlled humidity and oxygen level. It is ideal for use in Infant temperature recovery, resuscitation and other occasions.
Equipment standard by AKLION.
Specifications
- Mode of control
- Air mode and Baby mode controlled by / micro-computer
- Air temperature control range
- 20°C-37°C(override mode 37°C-39°C)
- Baby temperature control range
- 34°C-37°C(override mode 37°C-38°C)
- Accuracy of skin temperature sensor
- within ± 0.2°C
- The temperature fluctuation between incubator / temperature and average incubator temperature (under stable / temperature condition)
- ≤0.5°C
- Temperature uniformity
- ≤0.8°C(mattress is on the horizontal position) / ≤1.0°C(mattress is on the maximum tilt position)
- Inclination of the bassinet
- ± 12° (stepless adjustable)
- Noise inside hood (stable working condition)
- ≤50dB(A)
- Relative Humidity Level: / Humidity display range / Humidity control range / Accuracy of humidity display / Accuracy of humidity control
- 0%RH~100%RH / 0%RH~90%RH / ± 5%RH / ± 5%R
- Oxygen Level: / Indication range of oxygen concentration / Control range of oxygen concentration / Indication accuracy of oxygen concentration / Control accuracy of oxygen concentration
- 0%~100% / 20%~60% / ± 2% (The set value is below 25%) / ± 3% (The set value is above 25%) / ±4% 02
- Control Mode
- Pre-warm mode, manual mode and baby mode / are controlled by micro-computer
- Baby mode temperature control range
- 34°C-38°C
- Control accuracy ( The fluctuation range between Skin temperature and Set temperature)
- ≤0.5°C
- Temperature uniformity of mattress
- ≤2°C
- SPO2 Display range
- 1- 100%
- SPO2 Display resolution
- 1%
- SPO2 Alarm setting range
- Upper limit:50 ~100% / Lower limit: 45-95%
- PR Display range
- 25-240 bpm
- PR Display resolution
- 1bpm
- PR Alarm Setting range
- Upper limit: 80 – 240 bpm / Lower limit: 35-180 bpm
- PI Display range
- 0.02-20.0%
- PI Display Resolution
- 0.01%
- Sensitivity setting
- Normal,APOD, Max, / Factory default setting: Normal
- FastSAT
- off, on, Factory default setting: off
- Mean time
- 2S -4S, 4S-6S, 8S,10S, 12S, 14S, 16S / Factory default setting: 8S
- FailureAlarm
- Power Failure Alarm, Fan Motor Alarm, Sensor, FailureAlarm, Deviation Alarm, CanopyFailure Alarm, OverTemperature Alarm, Water tank placed false alarm, WaterShortage Alarm, SettingAlarnr Checking Alarm, System _ / Alarm, etc.
- Transportation
- Storage Temperature range: -20°C~+55°C / Relative Humidity range: ≤93% / Atmospheric pressure: 500hPa – 1060hPa
- Environment Requirement
- Operating range: 20°C-30°C(Set temperature / should be 3°C higher than the environment temperature) / Relative Humidity range: 30%~75% / Ambient air velocity rate: ≤0.3m/s
- Product Packaging
- Package: The whole unit is packed into one carton / Size: 1140mm x 660mm x 2315mm / Gross Weight: 160Kg
- Power supply / Power Requirement / Auxiliary Mains Power Output / Current
- AC220V-230V/50Hz / 1300VA / AC220-230V/50Hz, Max / 1A
Incubator Mode(Close Mode)
Infant Radiant Warmer Mode(Open Mode)
Performance Index Under Thepulse Oximetry