Infant Incubator DIXION BabyGuard I-1120 Transformer

Obstetrics & Gynecology

Infant Incubator BabyGuard Transformer

Choose model — 2 available

DIXION

Article No. AK-OG-013

Product details

Article number
AK-OG-013
Category
Obstetrics & Gynecology
Brand
DIXION

Description

For the provision of a similar maternal uterus environment for the neonate to provide stable and controlled comfortable thermal environment and servo-controlled humidity and oxygen level. It is ideal for use in Infant temperature recovery, resuscitation and other occasions.

Request a quotation

Equipment standard by AKLION — configuration, accessories and lead time are confirmed on the quotation.

Technical specifications

Mode of control
Air mode and Baby mode controlled by / micro-computer
Air temperature control range
20°C-37°C(override mode 37°C-39°C)
Baby temperature control range
34°C-37°C(override mode 37°C-38°C)
Accuracy of skin temperature sensor
within ± 0.2°C
The temperature fluctuation between incubator / temperature and average incubator temperature (under stable / temperature condition)
≤0.5°C
Temperature uniformity
≤0.8°C(mattress is on the horizontal position) / ≤1.0°C(mattress is on the maximum tilt position)
Inclination of the bassinet
± 12° (stepless adjustable)
Noise inside hood (stable working condition)
≤50dB(A)
Relative Humidity Level: / Humidity display range / Humidity control range / Accuracy of humidity display / Accuracy of humidity control
0%RH~100%RH / 0%RH~90%RH / ± 5%RH / ± 5%R
Oxygen Level: / Indication range of oxygen concentration / Control range of oxygen concentration / Indication accuracy of oxygen concentration / Control accuracy of oxygen concentration
0%~100% / 20%~60% / ± 2% (The set value is below 25%) / ± 3% (The set value is above 25%) / ±4% 02
Control Mode
Pre-warm mode, manual mode and baby mode / are controlled by micro-computer
Baby mode temperature control range
34°C-38°C
Control accuracy ( The fluctuation range between Skin temperature and Set temperature)
≤0.5°C
Temperature uniformity of mattress
≤2°C
SPO2 Display range
1- 100%
SPO2 Display resolution
1%
SPO2 Alarm setting range
Upper limit:50 ~100% / Lower limit: 45-95%
PR Display range
25-240 bpm
PR Display resolution
1bpm
PR Alarm Setting range
Upper limit: 80 – 240 bpm / Lower limit: 35-180 bpm
PI Display range
0.02-20.0%
PI Display Resolution
0.01%
Sensitivity setting
Normal,APOD, Max, / Factory default setting: Normal
FastSAT
off, on, Factory default setting: off
Mean time
2S -4S, 4S-6S, 8S,10S, 12S, 14S, 16S / Factory default setting: 8S
FailureAlarm
Power Failure Alarm, Fan Motor Alarm, Sensor, FailureAlarm, Deviation Alarm, CanopyFailure Alarm, OverTemperature Alarm, Water tank placed false alarm, WaterShortage Alarm, SettingAlarnr Checking Alarm, System _ / Alarm, etc.
Transportation
Storage Temperature range: -20°C~+55°C / Relative Humidity range: ≤93% / Atmospheric pressure: 500hPa – 1060hPa
Environment Requirement
Operating range: 20°C-30°C(Set temperature / should be 3°C higher than the environment temperature) / Relative Humidity range: 30%~75% / Ambient air velocity rate: ≤0.3m/s
Product Packaging
Package: The whole unit is packed into one carton / Size: 1140mm x 660mm x 2315mm / Gross Weight: 160Kg
Power supply / Power Requirement / Auxiliary Mains Power Output / Current
AC220V-230V/50Hz / 1300VA / AC220-230V/50Hz, Max / 1A