ri-thermo® Clibo Temperature Chamber

Functional Diagnostics

ri-thermo® Clibo Temperature Chamber 12468

Riester · 12468

Article No. AK-FD-419

Product details

Article number
AK-FD-419
Category
Functional Diagnostics
Brand
Riester
Model
12468

Description

The ri-thermo® Clibo temperature chamber has been specially developed for the regular verification of the measurement accuracy of Riester thermometers and helps you to ensure a consistently high level of patient safety in daily work in a medical practice. Especially for users of the tymPRO/tymPRO+ and sensioPRO/sensioPRO+ models, the temperature chamber enables a quick, standardised and evidence-based accuracy check under reproducible conditions. Thanks to the controlled temperature environment and excellent temperature stability (±0.03 °C at 37 °C), you benefit from reliable and repeatable results, which not only supports medical decision-making but also simplifies compliance with legal and billing-relevant requirements. The target temperatures can be freely selected within the range of 36.0 °C to 42.0 °C and can be displayed in both °C and °F, allowing you to carry out tests exactly according to your individual requirements. Operation is via an intuitive LCD display; integration into the workflow is straightforward and requires minimal time. Another advantage: The temperature chamber is housed in a robust, lockable case, thus meeting the highest safety standards during transport

Request a quotation

Equipment standard by AKLION — configuration, accessories and lead time are confirmed on the quotation.

Technical specifications

Brand
Riester
Model
12468
Product type
Thermometers
Accuracy
±0.1 °C / ±0.1 °F
Temperature stability
±0.03 °C at 37 °C
Measurement unit
°C (standard) or °F, switchable
Display
LCD
Heating stabilisation time
15 to 30 minutes
Power supply
100–240 V (50/60 Hz) / 3 A
Dimensions (L x W x H)
300 x 350 x 160 mm
Weight
4.3 kg
Case
suitable for transport, robust, with three-digit combination lock
Operating conditions
16 °C to 32 °C, 30–85 % relative humidity (non-condensing)
Storage/transport conditions
–20 °C to 55 °C, 30–85 % relative humidity (non-condensing)
Nominal emissivity
0.98 (suitable for infrared thermometry)
Certification
CE marking
Maintenance
Calibration check recommended every 2 years
Contact AKLION

Let's build the future of healthcare together.

Send us your project concept, department list or equipment requirements. AKLION will structure the solution.

Email Usinfo@aklion.de
Our OfficesRas Al Khaimah · UAE

Careers

AKLION is actively recruiting experienced specialists in the field of medical supply and comprehensive equipping of medical centres. We are looking for professionals who understand the full lifecycle of healthcare infrastructure — from equipment sourcing and logistics to turnkey installation and commissioning.

If you have a proven track record in hospital projects, biomedical engineering, healthcare procurement or project management within the medical sector, we invite you to apply below. We review every application personally and respond to shortlisted candidates within five business days.